skip to navigation

THE EXIT STORE : Exit Sign and Emergency Lights Specialists

Adagio Series Architectural Exit Sign

Adagio Series Architectural Exit Sign

Purchasing Info

Item Code:
ADGE
Base Price:
$45.00
Shipping Weight:
4.00 .lbs

NEED HELP?

866.471.2849

7am-7pm PST

Select Configuration

Operation
Letter Color
Housing Color
Options

Reset Configuration*

*As you select options, the configuration tool is equipped with active filtering to ensure valid combinations.

OVERVIEW

  • Download ADGE Spec Sheet

  • Download ADGE Installation Sheet

    Adagio Series Architectural Exit Sign with Emergency Lighting

    PRODUCT OVERVIEW

    The Adagio Series LED Exit Sign features a contemporary and compact housing design. The Exit stencil is articulated by a Long-Life LED light source that utilizes indirect refractive technology to provide evenly distributed illumination while assuring low maintenance costs and energy efficiency. The housing consists of durable injection molded thermoplastic with push-to-snap assembly, and comes optionally with a vandal resistant shield and tamper-proof screws. Available in single or double face configurations and ability to be wall(back), end(side), or ceiling(top) mounted. Easy to install canopy and field-selectable snap-in/out chevrons allow for quick and easy installation. The unit comes standard with a manual "Push to Test" button which can be optionally upgraded to include an onboard Self Testing and Diagnostic micro-controller to perform self-tests on a monthly basis while identifying as well displaying failures of the electrical components: battery, battery charger, or LEDs. The battery back up model comes with long life rechargeable NiCad. AC only versions are available in single or dual circuit (AC 120 or AC277)

    FEATURES

    • Indirect refractive technology provides bright, even illumination.
    • Exit sign long-life LED light source assures low maintenance costs and superior illumination.
    • Durable injection-molded thermoplastic housing with push-to-snap design. Optional vandal-resistant shield with tamper-proof screws.
    • Dual voltage input: 120/277 VAC. Optional advanced diagnostic circuitry, flasher/buzzer, fire alarm activated flasher.
    • Features Side, Top, and Back Mounting, Single Face/Double Face Design
    • Easy to install canopy and field-selectable snap-in/out chevrons for quick and easy installation.
    • UL924 Listed for Damp Location.
    • 5-year full warranty (excluding fuses), subject to proper installation and maintenance.

    Quick Glance

    Voltage Housing Colors Listing Dimensions
    120v/277v White, Black UL 924 Listed 11 7/8" x 2" X 8"
    Hertz Letter Colors Exit Illumination Body Material
    60Hz Red, Green LED Themoplastic
    Face Count Chevrons DC power Mounting
    Universal Pop Out / Pop In 6 to 48vdc Top, Back, End
    ADA Options Testing Method Consumption NEMA Rating
    Flasher, Buzzer Manual, Automatic Less than 3.5w Damp Location

    SPECIFICATIONS OVERVIEW

    The Adagio comes standard with a dual voltage input of 120/277VAC. The unit is suitable for wall back, wall side or ceiling top mount. The unit frame and face plates are made of injection-molded durable high-impact thermoplastic and come standard with snap in/out chevrons. No screws are necessary to hold the faceplate or back plate to the housing. The one piece thermoplastic frame is molded in white (optional black). The faceplates feature a uniformly illuminated legend. The exit sign light source is comprised of ALINGAP light emitting diodes (LED) that provide illumination in normal and emergency operation. An LED-sensitive diffuser is mounted behind the legend to provide the 6” high by 3/4” stroke letters with even illumination.

    The unit is equipped with a test switch and a green pilot light, located on the face plate above the EXIT legend. The battery charger is driven by a micro-controller. All electronic circuitry (charger, LED driver, LED’s) are installed on a single printed circuit board PCB.

    When equipped with Advanced diagnostics the circuit continuously monitors the performance of the battery, charger module and LED lamps. Upon failure detection the system displays the error on the AC pilot lamp, which will change color from green to red and will flash with a specific code. The pilot lamp will be steady-on red in case of “Battery Disconnect”; it flashes red with one blink for “Battery failure”, two blinks for “Charger failure” and four blinks for “LED lamp failure. A label with the diagnostic legend is visible next to the pilot lamp.

    EXTERNAL SPECIFICATIONS

    Adagio Premium Red LED Exit Sign
    Face Colors

    White or Black

    Housing Colors

    White or Black

    Mounting Ability

    Back (Wall), Side (End), Top (Ceiling), Pendant (Optional. Used when high ceilings are present to extend the sign lower. Requires Pendant stem length to be specified) .

    Housing Material

    The unit frame and face plates are made of injection-molded durable high-impact thermoplastic and come standard with snap in/out chevrons

    Temperature Rating

    50F to 110F Indoors.

    DIMENSIONS

    Adagio Premium Grade LED Exit Sign Dimensions
    Back Mounted

    Width: 17", Depth: 3 3/8", Height: 11 1/4"

    Exit Legend

    3/4" Stroke, Height: 6"

    MECHANICAL SPECIFICATIONS

    Exit Illumination Source

    High Efficiency, Long life ALINGAP LED technology using less than 3.5 watts.

    AC Power Consumption

    Energy efficient power consumption: less than 3.5 watts for self-powered version and less than 3 watts for AC only single or double face.

    Battery Type

    Standard: Maintenance Free Long Life NiCad.

    Performance Testing

    Self-Powered Models can be manually tested by pressing the test switch. Legend will flicker, but remain lit. On release, external green LED will illuminate, and automatic charger will restore battery to full charge.

    Models equipped with optional Automatic testing and diagnostics include a microcontroller which self-tests the unit on a monthly basis and identifies as well displays failures of the electrical components: battery, battery charger, lamps, LEDs.

    The self-test is performed every 30 days for 1 minute, every 6 months for 30 minutes, and annually for 90 minutes. The diagnostic function uses an external green LED indicator. Service is required if the green LED blinks indicating that an alarm condition is detected.

    Maintenance

    Long-Life ultra efficient LEDs ensure low maintenance and low electricity consumption.

    INSTALLATION

    Overview

    Standard universal design features snap-fit single/double face option with chevron pop outs for easily configuring no-arrow, left arrow, right arrow, or both arrow set ups as well as 120v/277v dual voltage capability.

    Adagio Premium Combo Exit Signs
    1. Turn off AC power.
    2. Route AC unswitched circuit of rated voltage into electrical box and leave 6” of wire length.
    3. Remove the exit door using a coin or a screwdriver at the top or bottom of the door.
    4. Determine the mounting position (end, wall or ceiling). Note: canopy is required for end or ceiling mount.
    5. The Adagio circuit system can accept input voltages of 120 VAC or 277 VAC. Therefore, connect the black (120 VAC) or orange (277 VAC) and white (common) leads to the building utility. Connect the Green wire to the ground. Unused primary wire must be insulated to prevent shorting
    Wall Mounting

    No canopy required is for wall mounting.

    1. With the help of a flat head screwdriver, knock out the proper hole pattern in the back cover to mount to a standard junction box.
    2. Feed the AC supply leads out through the center hole and make the proper connections. Feed the excess wire into the junction box and secure the back cover to the junction box using the junction box screws.
    3. Remove appropriate hole plug. Feed AC supply leads through side or top opening and then through canopy. Snap canopy on top or side of frame. Screw canopy to frame. In the case where a canopy lock is supplied, you may refrain from screwing the canopy to the frame and simply snap the canopy lock to canopy. However, for applications having a greater risk of exposure to abnormal impacts, we suggest to always use the canopy housing screw. Make the proper wire connections. The “Quick-install” canopy is equipped with ribs allowing you to hang the unit on the spider plate to facilitate wiring.
    4. Feed the excess wire into the junction box. Unhook unit and slide ribs on canopy into designated notches on the spider plate. Secure the canopy to the junction box using the canopy screw(s) provided.
    5. Remove the appropriate chevron(s) on the exit door by holding sign with both hands. Push chevrons from the inside with thumb. You may need to unsnap the diffuser panel to do so.
    6. Connect the battery
    7. Reinstall exit door(s).
    8. Energize AC. Sign will illuminate.
    End or ceiling mount

    For end of ceiling mounting, the canopy is required.

    1. Simply attach the spider plate to electrical box with the junction box screws.
    2. Remove appropriate hole plug. Feed AC supply leads through side or top opening and then through canopy. Snap canopy on top or side of frame. Screw canopy to frame. In the case where a canopy lock is supplied, you may refrain from screwing the canopy to the frame and simply snap the canopy lock to canopy. However, for applications having a greater risk of exposure to abnormal impacts, we suggest to always use the canopy housing screw.
    3. Make the proper wire connections. The “Quick-install” canopy is equipped with ribs allowing you to hang the unit on the spider plate to facilitate wiring. Feed the excess wire into the junction box. Unhook unit and slide ribs on canopy into designated notches on the spider plate. Secure the canopy to the junction box using the canopy screw(s) provided.
    4. Remove the appropriate chevron(s) on the exit door by holding sign with both hands. Push chevrons from the inside with thumb. You may need to unsnap the diffuser panel to do so.
    5. Connect the battery.
    6. Reinstall exit door(s).
    7. Energize AC. Sign will illuminate.

    There is no maintenance required for the batteries of Self-Powered Models. If AC supply to the unit is to be disconnected for 2 months or more, the battery must be disconnected. Note — NiCd (Nickel Cadmium) batteries are shipped discharged and may require 10 minutes of connection to AC supply before start-up test procedure, and 96 hours to reach full charge.

    Electrical Connections

    120v/277v 60hz Dual Voltage, 120v/120v Dual Circuit, 277v/277v Dual Circuit, DC Input 6v to 48v

    OPTIONAL FEATURES

    • -BA= brushed aluminum exit stencil
    • -FZ= flasher buzzer
    • -FL= flasher
    • -FA= fire alarm activated flasher
    • -FBF= flasher buzzer + fire alarm activated flasher
    • -ADNA= advanced diagnostics nonaudible (not available with 1250H )
    • -AD= advanced diagnostics
    • (not available with 1250H )
    • -VR= tamper proof screws
    • -VR1= polycarbonate shield with
    • tamper proof screws
    • -KIN= Kinesis wired
    • -KINRF= Kinesis wireless

    ACCESSORIES

    • Wire Guard
    • Pendant Kit

    The unit can be ordered with vandal/tamper screws.

    APPLICATIONS

    The Adagio series is UL Listed for dry or damp indoor locations. The modern design comfortably suits retail, office, commercial, hospital, and hotel type installations.

    COMPLIANCES

    UL Listed for dry and damp locations to UL924 specifications. Not Suitable for City of Chicago or NYC (5 Boroughs).

    WARRANTY

    5 year full warranty* excluding fuses and lamps. *Must be installed as directed.

    ENVIRONMENTAL RATINGS

    Indoor Dry and Damp Locations. Typical setting: Offices, Hospitals, Retail