skip to navigation

THE EXIT STORE Exit and Emergency Specialists

Adagio Series Architectural Grade MR16 Emergency Lights

Item Code:
ADGL

Categories this can be found in:
Buy American Emergency Lights : Emergency Lights : Buy American Compliant Exit Signs :

Adagio Series Architectural Grade MR16 Emergency Lights

Purchasing Info

Base Price:
$134.99
Shipping Weight:
5.00 .lbs

NEED HELP?

866.471.2849

7am-7pm PST

Select Configuration

Operation
Housing Color
Lamp Type
Options

Reset Configuration*

*As you select options, the configuration tool is equipped with active filtering to ensure valid combinations.

OVERVIEW

Adagio Series Architectural Grade MR16 Emergency Lights

  • Download ADGL Spec Sheet

  • Download ADGL Installation Sheet

    PRODUCT OVERVIEW

    The Adagio ADGL Series Emergency Light housing design is compact, stylish, and contemporary. It features the ability to support up to 72 watts of lighting load for 90 minutes; unprecedented for a design of this type. Bottom mounted MR16 heads are available in halogen or LED light sources and feature a rotating axis allowing for superior adjustability. The sleek housing design is articulated by the stylish aluminum light fixtures shielded and visible through the shaped clear polycarbonate lenses. The beautifully simple and balanced 2-piece thermoplastic injection molded body houses state-of-the-art electronics powered by sealed maintenance-free lead calcium or Nickel-Cadmium batteries. The unit comes in a variety of load capacities, the largest being capable of powering up to a 72 watts load for a period of 90 minutes. Alternatively, you can opt to use that maximum 72w load capacity to extend the 4w LED MR16 heads for over 8 hours of emergency illumination. The unit comes standard with a manual testing method for OSHA compliance that can be optionally upgraded to include integrated Self-testing and Self-Diagnostic circuitry. The Self-Diagnostics module is available with an audible and non-audible alert. The Adagio Series Emergency Light is UL Listed, equipped with dual voltage 120/277v transformers standard, available with a damp location rating, and can be equipped with an emergency operation mode shut off 15-minute time delay. The standard unit is capable of back wall mounting, as well as, ceiling mounted using the optional ceiling mounting kit. The unit is available in a white or black housing.

    FEATURES

    • UL924 Listed
    • 120/277v standard
    • High efficiency Halogen MR16 lamps up to 12V, 20W or ultra efficient white 4w Luxeon LED heads
    • Available with Continuous self-diagnostic monitoring and monthly self-testing
    • Fully automatic charger is solid state
    • Wall or Ceiling Mountable
    • Damp Location Rating Available
    • Lead Calcium or NiCad batteries for up to 72 watt load
    • White or Black Housing

    SPECIFICATIONS

    The Adagio ADGL unit is able to provide emergency lighting with its entire electronics and power source in a slim two-piece compact thermoplastic housing.

    The emergency lighting MR16 heads are located at the bottom of the unit and covered by a sealed clear lens made of UV-stabilized polycarbonate. These emergency lighting heads are equipped with an innovative swivel system allowing for up to a 180 degree rotation in order to provide for an illumination in any direction of the path of egress.

    The Advanced Diagnostic Micro-controller board supplies the rated load for a minimum of 90 minutes to 87.5% of the rated battery voltage. The unit is rated 120/277 VAC, 60Hz and is UL listed. The unit is capable of a remote load. The charger first continuously recharges the battery then, when the battery is at full capacity, the charger periodically pulse charges the battery in stand-by mode. This pulse-type charger promotes long battery life and reduces the potential for grid corrosions. Its charge voltage is factory set to +/-1% tolerance and is temperature compensated. The charger incorporates Lockout and Brownout Circuits, and Low Voltage Disconnect. It protects the unit from over-current, short-circuit, and reverse polarity.

    When equipped with the Self-diagnostic and testing option, the unit self-tests for 1 minute every 30 days, 30 minutes on the 6th month and 90 minutes every 12 months. The unit is capable of full recharge in compliance with UL specifications. The unit is supplied with a magnetic test switch. A "Service-Required" lamp is located near the test switch and flash when a fault is detected. A LED-based diagnostic display is located inside the equipment and identifies the source of failure (battery, charger, circuitry, or lamps).

    EMERGENCY OPERATION

    When in emergency mode the exit remains illuminated and the emergency lights automatically turn on. The unit is capable of operating in the event of a power loss using self-contained battery for a minimum of 90 minutes per UL924. When AC power returns to the unit, the emergency lights will turn off. The Time Delay function (TD) is recommended when the battery unit is installed in areas normally illuminated by high-intensity discharge (HID) lamps, like: metal halide or high-pressure sodium lamps. When enabled, the Standard Time Delay function maintains the emergency lights -ON- for 15 minutes after the AC main power is restored. The Time Delay Function can be enabled or disabled in the field.

    Adagio Emergency-Light Dimensions Black Housing LED MR16

    EXTERNAL SPECIFICATIONS

    Housing

    The Adagio ADGL Series Emergency Light is made of injection molded thermoplastic that is available with an option damp location listing. The unit comes in a choice of two colors: white or black. The clear lenses are UV stabilized and made of polycarbonate. They are shatterproof. The unit comes standard capable of back, wall surface mounting, but can be optionally ordered with a ceiling mounting bracket.

    Housing Colors

    White, Black

    Mounting Ability

    The unit comes standard with surface wall back mounting, but can be optionally ceiling mounted by ordering the kit.

    Housing Material

    The unit is comprised of injection molded thermoplastic. The lenses are clear UV stable shatterproof polycarbonate.

    Environmental Rating

    The unit is designed for indoor use in dry locations standard. It can be ordered with a Damp Location rating.

    DIMENSIONS

    Adagio Emergency-Light Dimensions

    Depth:3.87" Width:12.25" Height:10.62"

    MECHANICAL SPECIFICATIONS

    The equipment comes standard with a dual voltage input of 120/277 VAC. The unit is standard equipped with a manual test. The unit is optionally equipped with the fully automatic Advanced Diagnostic micro-controller board. The micro-controller tests, detects and indicates battery, charger circuitry, or lamps failures. An external LED signals a general service alarm while an internal diagnostic LED display indicates the nature of failure. The board is capable of audible or non-audible diagnostic and a 15 minutes time delay. These functions must be enabled at factory.

    Illumination Source

    The fully field adjustable emergency lighting heads can be equipped with standard High Intensity MR16 halogen lamps up to 20w or MR16 white LED lamps ( lamp consumes 4 Watts and uses a 3-Watt white Luxeon LED )

    Remote Capacity

    This unit is capable of supporting a load capacity of 72 watts at 12 volts, some of which may be remote.

    Charger

    Unit comes with a sealed, maintenance-free Lead Calcium or Nickel-Cadmium battery.

    Performance Testing

    The unit can be manually tested. When order with the Self-Testing/Self-Diagnostic option, this unit self-tests for 1 minute every 30 days, 30 minutes on the 6th month and 90 minutes every 12 months. The unit is capable of full recharge in compliance with UL specifications. The unit is supplied with a magnetic test switch. A "Service-Required" lamp is located near the test switch and flash when a fault is detected. A LED-based diagnostic display is located inside the equipment and identifies the source of failure (battery, charger, circuitry, or lamps). Optional Audible Diagnostics alert is available.

    You operate the magnetic "test switch" by holding the provided magnet near the AC pilot lamp, where indicated on the legend. This will initiate a one minute test. The DC lamps will illuminate for approximately one minute, then the unit will automatically return to stand by mode. Test can be cancelled by holding the magnet near the test switch again.

    There are five diagnostic indicators: one external and four internal. Unit must be opened to gain access to internal indicators. External: General alarm, "Service Required". The LED will turn-on if any alarm condition is detected. Internal: Battery Failure, Battery Disconnect, Charger Failure & Lamp Failure. Steady ON if alarm condition exists. Normal operation, No fault - "Service Required" is OFF. Faulty operation - "Service Required" is ON.

    This is a multi-function indicator related to battery condition. This indicator will be illuminated when a wrong battery (ex: 6V battery on a 12V system or vice versa) or a completely depleted battery (battery voltage less than 65% of nominal) is connected to the circuit - Allow 24 hours recharging if the battery voltage is between 25% and 65% of nominal - it will also be illuminated if the battery has failed a timed or forced test (reached LVD level before the end of the test). In the case of incorrect battery, the circuit will disable the charge current.

    Maintenance

    The charger first continuously recharges the battery then, when the battery is at full capacity, the charger periodically pulse charges the battery in stand-by mode. This pulse-type charger promotes long battery life and reduces the potential for grid corrosions. Its charge voltage is factory set to +/-1% tolerance and is temperature compensated. The charger incorporates Lockout and Brownout Circuits, and Low Voltage Disconnect. It protects the unit from over-current, short-circuit, and reverse polarity.

    INSTALLATION

    Mounting

    wall(back) or ceiling with optional bracket.

    Electrical Connections

    Using the sealed AC nipple/wire assembly (3 wires), connect one end to the transformer leads, inside the enclosure, and the other end, to AC line voltage inside the junction box. Connect the white lead to neutral and the green lead to ground. Connect the purple lead to AC line voltage and to appropriate transformer lead. Unused primary wire must be insulated to prevent shorting.

    • Standard Input: 120/277Vac 60Hz
    • Remote Load: DC 6v, DC 12v with total wattage capacities including all heads not exceeding 87.5 of total battery voltage.

    OPTIONAL FEATURES

    • Advanced Diagnostics / Audible or Non-Audible
      Audible alerts when system detects irregularity.
    • Kinesis Connect
      Wired and RF monitoring

    ACCESSORIES

    • Wire Guard

    APPLICATIONS

    • Indoor Dry and Damp Location
    • Commerical
    • Libraries
    • Hospitals
    • Hotels
    • Resorts
    • Office Buildings
    • Restaurants
    • Schools and other public facilities

    COMPLIANCES

    UL924 Listed, Damp Location

    WARRANTY

    5-year full warranty (excluding lamps, batteries and fuses) when installed as instructed.

    Batteries are covered under a 5 year prorated warranty

  • back on top